New in Miljöbyggnad 1.02 (relative to 1.01): ============================================ + Daylight plane names changed to "Användardefinierade". + Simulation date of each indicator run is now written in the report heads. + Removal of Column "Plan" in reports for indicator runs 3,10,11,12. + Changed to include also latent heat in "Bortförd värme, ventilation" for indicator 11. Fixed bugs: ============================================ + Wrong text: Report indicator2, 2.8: "Hantering av köldbryggor om *<* 20% av transm.förluster". + Wrong text: Report indicator10, Indata 10.18: "fönsters U-värde". + g-syst was taken from possibly wrong month, for indicator runs 3 and 11. + Reporting of schedule was sometimes wrong if more than two schedlues were used in a room. + Skylights crashed the report generation. + Improvement of routines for automatic placement of occupant for indicators 10 and 11. + Total grade was Silver instead of Gold for indicator 12.